ZLF (-45 ~ 250℃)
- Temperature Range-45 ~ 250℃
- Temperature Control Accuracy±1℃
- Heat Exchanger Area3.5 ~ 20m³
- Circulating Pump Flow and Pressure150~750L/min 2.5BAR
- Power Supply380V 50HZ 2.3~10.5KW
- Place of OriginChina
- Quality Guarantee Period12 months
FEATURES:
LNEYA-TCU temperature control system can realize -120°C to 300°C of dynamic temperature control, using existing thermal energy (such as steam, cooling water and ultra-low temperature liquid – that is, “primary system”) infrastructure integration for control Process equipment temperature in a single fluid system or secondary circuit. This completes the flow of only one heat transfer liquid into the jacket of the reaction vessel (rather than directly into the steam, cooling water or cryogenic liquid). The entire reaction process temperature is controlled by calculation.
Through three-point sampling (material temperature point, temperature control system outlet temperature, temperature control system inlet temperature), and our own model-free self-built tree algorithm and general anti-lag cascade algorithm, solve the problem of large delay in pharmaceutical chemical temperature control .
Model | ZLF-35N ZLF-35NS ZLF-35NH ZLF-35NSH | ZLF-50N ZLF-50NS ZLF-50NH ZLF-50NSH | ZLF-80N ZLF-80NS ZLF-80NH ZLF-80NSH | ZLF-125N ZLF-125NS ZLF-125NH ZLF-125NSH | ZLF-200N ZLF-200NS ZLF-200NH ZLF-200NSH |
Temp. range ℃ | -45~ 250degree (setting the max temp according to the supplier heating or cooling source) -40~135degree(The maximum temperature range can be operated by using glycol water formula.) | ||||
ZLF- N | The main cold source/or main heat source is used to regulate the flow of the system through proportional regulation system, and control the heat of the clamping of the reaction tank, and a set of heat exchanger for heating or cooling is controlled or cooled. | ||||
ZLF- NS | Besides ZLF- N function,add one set heater used to reduce high temp. | ||||
ZLF- NH | Besides ZLF- N function,add electrical heating function | ||||
ZLF- NSH | Besides ZLF- N function,add one set heater used to reduce high temp and electrical heating function | ||||
Heat exchanger area | 3.5m2 | 5m2 | 8m2 | 12.5m2 | 20m2 |
Electric heating function H | 25KW | 35KW | 50KW | 65KW | 80KW |
With “H” has heating function | |||||
Control mode | Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller | ||||
Communication protocol | MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface | ||||
Temp control selection | Process temp control | ||||
Temperature feedback | The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor | ||||
Process temp. feedback | Raw material process feedback:PT100 or 4~20mA or communication given Temp. feedback:PT100 | ||||
temp feedback: normal PT100 | |||||
Temperature accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
Circulation pump | 150L/min 2.5BAR | 200L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | 750L/min 2.5BAR |
Input and display | 7-inch color touch screen,temperature graph display | ||||
Safety protection | Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection. | ||||
Perform valve piece | Electric proportional control valve, control signal 4~20mA. | ||||
Piping material | SUS304 | ||||
Connection size | DN40 | DN40 | DN-50 | DN-65 | DN-80 |
Dimension cm | 150*120*185 | 180*120*210 | 180*120*210 | 225*120*240 | 225*120*240 |
Power AC380V50HZ | 2.3kw(max) | 3.5kw(max) | 4.5kw(max) | 8kw(max) | 10.5kw(max) |
With H power AC380V 50HZ | 27.3kw(max) | 38.5kw(max) | 54.5kw(max) | 73kw(max) | 90.5kw(max) |
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS304 |